Adding pinned uuid for rootfs
This commit is contained in:
@@ -113,6 +113,23 @@ boot LAN.
|
||||
writable → multi-user.
|
||||
- This validation **gates** item #1 (network-manager port) and item #3
|
||||
(errata → design v3).
|
||||
- **Bench findings (boot debug, 2026-06-14):**
|
||||
- Initramfs has no resolver (dracut writes `resolv.conf` only via its own
|
||||
DHCP path, not a manual `dhclient`), so the NVMe discovery address must be
|
||||
an **IP**, not a DNS name — build with `-var nvmet_traddr=192.168.50.10`.
|
||||
Old UKIs carrying `nvme.fleet.lab` can't connect early in boot.
|
||||
- NVMe controller indices are **not stable**: a transient discovery
|
||||
controller can take `nvme0`, pushing the I/O controller to `nvme1`. The
|
||||
hardcoded `/dev/nvme0n1` in the cmdline was a latent brick. **Fixed:**
|
||||
namespace UUID pinned on the target (`spdk-setup.sh` `add_ns -u
|
||||
f1ee7000-0000-4000-8000-000000000001`) and the cmdline now references
|
||||
`/dev/disk/by-id/nvme-uuid.<uuid>` (`extract-artifacts.sh`). The two
|
||||
constants MUST stay in sync; make them version-specific for #6.
|
||||
- `nvme_tcp`/`nvme_fabrics` must be loaded before `/dev/nvme-fabrics` exists
|
||||
(dracut's `nvmf` module does this in a normal boot; at `rd.break` modprobe
|
||||
manually).
|
||||
- SPDK: add the listener to the discovery subsystem explicitly
|
||||
(`nqn.2014-08.org.nvmexpress.discovery`) to silence the deprecation warning.
|
||||
|
||||
## [ ] 6. Rolling fleet updates (multi-version serve → cohort reboots)
|
||||
|
||||
|
||||
Reference in New Issue